Addressed an issue where the server may assign incorrect ACPI NUMA proximity allocations for servers configured with two or more processors and with memory only attached to a single processor socket potentially leading to non-optimal performance. The list of recommended drivers for your product has not changed since the last time you visited this page. Added support to detect and log when memory performance may be degraded due to a high rate of correctable memory errors. Addressed an issue where the UEFI iSCSI Software Initiator boot options may become invalid if the DHCP server provides a new IP Address to a previously configured iSCSI boot option. 3. Obtain a formatted USB Key media. A firmware update of the fibre channel controller might also be required to take full advantage of this feature. This issue only affects servers configured in Legacy Boot Mode. Addressed an issue where the server would display a Red Screen error and become unresponsive when exiting the System Utilities Embedded User Diagnostics when configured for Legacy Boot Mode. In addition, added a new Firmware Information menu to System Information to provide a list of current firmware revisions for supported components.   Updated the system thermal logic to support the NIVIDIA P4000 GPGPU. This revision of the System ROM includes the latest revision of the Intel microcode which addresses an issue where the system could experience an unexpected reset or shutdown with no errors logged to the Integrated Management Log (IML). ... Operating System: Microsoft Windows Server 2008 (64-bit) dear all . Deploy the data center standard Addressed an issue where the system may become unresponsive and experience a Machine Check Exception or NMI under heavy stress conditions when configured with Intel Xeon E5-2600 v3 processors and 64GB LRDIMMs in a 3 DIMM Per Channel configuration. This issue only impacted a system when configured for legacy boot mode. Added support for Microsoft Windows 2019. Addressed an extremely rare issue where the system may experience a "266-Non-Volatile Memory Corruption Detected" message and Integrated Management Log (IML) event after being powered down from a momentary power button press. Addressed an issue in the HP RESTful API BIOS support that resulted in internal HTTP sessions between BIOS and iLO left open during boot. Addressed an issue where the system may become unresponsive during system boot when a USB-based UPS is attached to the server USB ports. Addressed an issue where the system health LED would remain blinking RED (indicating a failed state) due to a power supply failure after the power supply had been replaced. Search. This issue only impacts systems configured with Intel Xeon 2600 v4 series processors. Addressed an issue where the HP ProLiant Dynamic Power Regulator would not function properly when configured for Slow Mode. When this condition is detected, a new Integrated Management Log (IML) message will be logged indicating a "High rate of corrected memory errors, performance may be degraded". Addressed an issue where the server might become unresponsive after looping through the UEFI Boot Order an extended amount of time when no valid boot targets are detected. With this revision of the System ROM, the system will properly display a message indicating the error and halt the boot process. This will allow an optional PCIe USB controller, such as available on the Teradici PCoIP Zero Client card, to be functional in a pre-boot environment. Product Bulletin, research Hewlett Packard Enterprise servers, storage, networking, enterprise solutions and software. Wait until the installation has finished then click on continue. Added support to the Embedded UEFI Shell to allow the user to export Secure Boot certificates to a file. Note: The system will attempt to boot all UEFI bootable USB devices in the order of the Generic USB Boot entry even if installed individual USB devices are configured lower in the boot order. HP ProLiant DL380 Gen 9 furnishes a high-performance rack solution. HPE ProLiant DL360/DL380 Gen9 System ROM - P89 Â. Addressed an issue where the +/- keys in the BIOS/Platform Configuration (RBSU) Boot Options menu were not functioning properly when configuring the server through a BIOS Serial Console Session. Upgrade Requirement:Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version. How does HP install software and gather data? Added a Server Security BIOS/Platform Configuration (RBSU) option to Enable or Disable "Processor AES-NI Support". Updated help documentation for System Utilities and the Embedded UEFI Shell. Previous revisions of the System ROM defaulted to scanning all targets. This issue does not affect systems where the UEFI iSCSI Boot Configuration is configured through the System Utilities BIOS/Platform Configuration (RBSU). Addressed an issue where the Administrator Password would not be properly configured from the Embedded UEFI Shell Sysconfig command. 2. They are usually only set in response to actions made by you which amount to a request for services, such as setting your privacy preferences, logging in or filling in forms. HP P89 . Solved: hello, where to find the latest bios for dl380 Gen9 server ? Previously, the system would become unresponsive during boot with no indication of a failure. Please wait, this may take a few moments…” Note: BIOS P89 v.2.40 is part of the HPE SPP from April 2017 (SPP 04/2017) HP can identify most HP products and recommend possible solutions. How does HP use product data collected with this service? This option enables or disables the Advanced Encryption Standard Instruction Set. Addressed an issue where the system may shutdown when a fatal error occurs in the pre-OS environment (such as the System Utilities or Embedded UEFI Shell) and not log any entry into the Integrated Management Log (IML). Addressed an extremely rare issue where the system may receive a Red Screen error and become unresponsive during boot. Addressed an issue where the system may fail to boot from existing UEFI iSCSI Software Initiator boot options if the user changed the iSCSI Target IP address. Javascript is disabled in this browser. This option is only available in UEFI Boot Mode. This option can be selected from the Advanced Memory Protection Mode selection. Disk HP LOGICAL VOLUME . Added a new System Utilities BIOS/Platform Configuration (RBSU) Internal SD Card Slot menu located in USB Options that allows the user to disable boot from the embedded SD card. Addressed an issue where industry standard SMBIOS Type 9 entries for PCIe Slots attached to a not installed processor did not exist. Added support for a Compress command in the Embedded UEFI Shell. This page requires Javascript. Added support to Standard Format Output (SFO) to the SysConfig command in the Embedded UEFI Shell. For Proliant Gen8/9/10, HP has released a new firmware (ROM) to mitigate the impact of Meltdown and Spectre. Updated the HP RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options. Addressed several issues with the legacy USB support (USB support before the operating system loads) when the system is configured for Legacy Boot Mode. Added support to the HP RESTful API to allow the user to configure the UEFI boot order when the system is configured for Legacy Boot Mode. This change only prevents the display of the erroneous message and does not impact USB functionality. Download the SoftPaq to a directory on a system running Microsoft Windows 2000, Microsoft Windows XP, Microsoft Windows Vista, Microsoft Windows 7, Microsoft Windows 8, Microsoft Windows Server 2003, Microsoft Windows Server 2008, Microsoft Windows Server 2008 R2 or Microsoft Windows Server 2012 and change to that directory. Addressed issues with USB support in the pre-boot environment when the system is configured in Legacy Boot Mode. This may help resolve issues of intermittent connection drop during an iSCSI boot. Addressed an issue where changing the boot order using the HP RESTful Interface may result in the system not responding to key presses for F9 (System Utilities) or F11 (Boot Menu) during subsequent system boot. Addressed an issue where the ambient temperature reported by the system during server boot may report incorrectly. Hp proliant dl380 … Addressed an issue in accessing the file systems or booting to some RAID0 logical volumes off HP Smart Array controllers. This includes addressing an issue where the system might log a 303/304 Keyboard controller failure error when certain USB KVMs are attached to the system. Hi community, since one week we have new DL380 Gen9 servers. Addressed an issue where the Legacy Boot Order menu in the System Utilities BIOS/Platform Configuration (RBSU) might have incorrect port numbers when the server is configured in Legacy Boot Mode. Added a new System Utilities Embedded Applications Active Health System Log option. This issue is not unique to HPE servers. This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-0151. Addressed an issue where the HP RESTful API and Embedded UEFI Shell description of the storage controller may begin with an instance of 2 instead of 1 when only one storage controller was installed in the server. When this issue occurs, USB support still functions properly under the operating system and the error message is erroneous. Industry standard SMBIOS tables were NOT updated to reflect Hewlett Packard Enterprise branding. This also addresses an issue in configuring the server UEFI Boot Order using HP OneView and the HP RESTful API. Help. Addressed an issue where an erroneous 312 - HP Smart Battery error message would be displayed and logged to the Integrated Management Log (IML) on the first boot after the system battery was removed from the server. By default, the time is formatted for Coordinated Universal Time (UTC). HP's Virtual Agent can help troubleshoot issues with your PC or printer. Updated the UEFI Secure Boot Key Database revocations list (DBX) with the latest version from Microsoft. The command can be used to compress and decompress ZIP files. The user can now optionally select to use the DUID-LLT as the unique identifier for PXE Boot. Addressed an extremely rare issue where the server may become unresponsive due to a Non Maskable Interrupt (NMI) when performing a shutdown or startup from an Operating System. Added support for the industry standard SMBIOS Type 2 baseboard record. The HPE ProLiant DL380 Gen9 Server delivers the best performance and expandability in the Hewlett Packard Enterprise 2P rack. The list of all available drivers for your product is shown above. 2. Addressed an issue where a server configured for UEFI boot mode may become unresponsive during boot when configured with an optional graphics controller that does not support UEFI boot mode. English. After deploying BIOS P89 v2.40 (02/17/2017) and/or ILO Firmware 2.50 (09/23/2016) an HP DL380 Gen9 Server stops during early BIOS boot sequence at the following message: “Starting drivers. Addressed an issue where the server may become unresponsive when using the PING command from the Embedded UEFI Shell. dear all i have lost SmartStart CD for HP Proliant DL380 G9 , where i can download that software becouse i can;t install windows if not use - 5964269 ... Lost SmartStart for DL380 Gen9 ‎01-30-2017 02:59 AM. The DL380 provides the next-level performance and expansion options you’ve come to … When Network VLAN Configuration is enabled, the server would always attempt to boot both iPV4 and iPV6 regardless of the PXE Boot Order Policy setting. This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigation for an Intel sighting where the system may experience a machine check after updating to the latest System ROM which contained a fix for an Intel TSX (Transactional Synchronizations Extensions) sightings. The command can be used to display the Secure Boot keys and certificates. Addressed an issue where the Automatic Server Recovery (ASR) setting may not be configured properly through the HP RESTful API. 5. This type of PCI-express card implementation is more common with older PCI-express expansion cards. If you have the SPP version, please share so that we can share the content report which gives the detailed information of respective SPP. The URL describing the network (HTTP or FTP) location of the startup script can be configured in the System Utilities /Platform Configuration (RBSU), under the Embedded Shell menu. This mitigation is only needed for systems that have TXT enabled (TXT is disabled by default). This option provides enhanced memory availability and resiliency but requires additional memory be installed to achieve the same amount of memory available to the operating system. This option allows users to download Active Health System (AHS) Logs. This issue would not be seen if the ROM Based Setup Utility (RBSU) Option for Dynamic Power Calibration is set to Disabled (the default for this option is Auto which could result in this issue). 3. The network settings (DHCP or static IP) and boot file URL can be configured in the new System Utilities BIOS/Platform Configuration (RBSU) Pre-Boot Network settings menu. We were unable to retrieve the list of drivers for your product.  Please select the desired operating system and select “Update” to try again. Enhanced the UEFI Exception handler to provide extended debug and trace information when in a pre-OS environment. What is HP ProLiant DL380 Gen9 End of Life (EOL)? Only compatible Firmware and Drivers for the product will be displayed on this page. ... "The software will not be installed on this system because the required hardware is not present in the system or the software/firmware doesn't apply to this system." A Medium level CVE has been assigned to this issue with ID CVE-2018-3639. RECOMMENDED * System ROMPaq Firmware Upgrade for HPE ProLiant DL360 Gen9/DL380 Gen9 (P89) Servers (For USB Key-Media) - 2.76_10-21-2019 (A) Nov 13, 2019 Will start by installing the BIOS via USB key. Addressed an issue where HP Smart Array error messages are not logged to the Integrated Management Log (IML).   https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00060570en_us. Updated the HpBiosAttributeRegistry resources to match the latest BIOS/Platform Configuration options. Specifications page for HP DL380z Gen9 Virtual Workstation. This setting is applicable only in UEFI Boot Mode. Get advice, answers, and solutions when you need them. Save your personal devices and preferences, Managing contracts and warranties for your business, For Samsung Print products, enter the M/C or Model Code found on the product label. Addressed an issue where an optional PCIe adapter's legacy Expansion ROM may not run properly or the Expansion ROM's Setup Utility may not run properly when the server is configured for Legacy Boot Mode. This issue is NOT unique to HP servers. HPE ProLiant DL380 Gen9 Server: Access product support documents and manuals, download drivers by operating environment, and view product support videos and forum discussions. The PC you are currently using does not match the PC you have selected. Hewlett packard enterprise. Please wait while we gather your contact options. Upgrade Requirement:Recommended - HPE recommends users update to this version at their earliest convenience. System ROMPaq Firmware Upgrade for HPE ProLiant DL380 Gen9/DL360 Gen9 (P89) Servers (For USB Key-Media) By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement. While updating to this revision of the BIOS will not address this issue unless the iLO FW revision is later than 2.4x, there are no issues caused by updating the BIOS without updating iLO FW. The iSCSI network settings can be configured in the new System Utilities BIOS/Platform Configuration (RBSU) iSCSI Boot Configuration menu, as well as using the HP RESTful API HpiScsiSoftwareInititiator resource type.  Additional information is available from Intel’s Security Exploit Newsroom, https://newsroom.intel.com/press-kits/security-exploits-intel-products/. Addressed an issue where the system health LED would remain blinking AMBER (indicating a degraded state) due to an installed power supply not being plugged in after the power supply had been plugged in.